Filter Results By:

Products

Applications

Manufacturers

Showing results: 31 - 45 of 48 items found.

  • PXIe-4136, 200 V, 1 A System PXIe Source Measure Unit

    783760-01 - NI

    ±200 V, 1 A System PXI Source Measure Unit—The PXIe‑4136 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4136 features 4-quadrant operation. The PXIe‑4136 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.

  • PXIe-4138, 60 V, 3 A System PXI Source Measure Unit

    782856-01 - NI

    ±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.

  • PXI-4132, 100 V, 2 W Precision PXI Source Measure Unit

    780558-01 - NI

    ±100 V, 10 pA Precision PXI Source Measure Unit—The PXI-4132 is a programmable, high-precision source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4-wire) sense as well as external guarding. With its high measurement resolution integrated guarding, the PXI-4132 is ideal for high-accuracy leakage measurements on integrated circuits, discrete components, PCBs, and cables. You can also perform high-speed I-V measurements on a variety of components including diodes and organic LEDs using the onboard hardware sequencing engine. In addition, you can synchronize multiple PXI-4132 modules using the PXI backplane to provide high-speed I-V measurements on transistors and more complex devices.

  • Incoherent Sources

    Thorlabs, Inc.

    Our Incoherent Sources include unmounted LEDs, mounted LEDs, collimated LEDs, LED light sources, superluminescent diodes, and broadband light sources. Our collimated LEDs are particularly popular and are compatible with many microscopes. Versions are available with center wavelengths from the UV into the NIR or that emit white light.

  • *Energy Sensors For IPL Sources

    mks Ophir

    Ophir has several ways to measure intense pulsed light IPL radiation used in cosmetic treatments. The light from these sources is broadband and usually has a high divergence. Furthermore, the light source is often coupled to the skin via an index matching gel. For these reasons, we need special solutions to accurately measure the energy of the IPL pulses.

  • Light

    Thorlabs, Inc.

    Welcome to Thorlabs; below you will find links to light emitters, sources, and controllers, a subset of our entire line of photonics products. Our light sources are conveniently separated into coherent and incoherent sources. The coherent source category includes laser diodes, laser diode modules, tunable lasers, HeNe lasers, and femtosecond lasers, while the incoherent source link brings you to a selection of LEDs, white light, and broadband SLD sources. The Quantum Electronics category includes optical amplifiers, modulators, and gain elements that are frequently used in research and OEM applications. All of our light sources and optical amplifiers are supported by an extensive line of mounts, sockets, TEC controllers, and current controllers.

  • Laser-Driven Light Source (LDLS)

    EQ-77 - Energetiq Technology, Inc.

    Based on the highly successful Laser-Driven Light Source (LDLS)technology, the EQ-77 offers the highest radiance and irradiance availablein a truly broadband white light source. The EQ-77 features a compact lamp house, with clean construction that ensures long life and ultimate stability. With a 170nm-2100nm wavelength range, and a choice of source dual-beam output or a single-beam output with retro-reflector, the EQ-77 is flexible for a broad variety of applications. Researchers using light for imaging and analytical spectroscopy in a variety of applications in the life sciences and materials sciences need light sources capable of providing extreme high brightness and power across a broad wavelength range.

  • Supercontinuum White Light Lasers

    SuperK series - NKT Photonics A/S

    The SuperK series is an industry-leading range of turn-key supercontinuum white light lasers used by the most innovative companies within bio-imaging, semiconductor inspection, sorting, device characterization, and scientific instrumentation. The sources are robust and reliable, built for intensive use, and can replace multiple single-line lasers as well as broadband sources like ASE sources, SLEDs and lamps.

  • Economical Solution for Test Requiring Fewer Instrumentation Modules.

    OPTOWARE-S200 (FOTS-Bench Top Series) - Notice

    •LD Driver, EDFA, ASE Broadband Source, 1X4 Optical Switch•Variable Optical Attenuator, Wavelength Meter•SOA Driver, SLED Driver, Pump LD Driver•Pattern Generator & BERT, SFP Transceiver Driver•4Channel Optical Return Loss Meter (Light Source & Power Meter)

  • FOTS-ORL

    S-120 - Notice

    •LD Driver, EDFA, ASE Broadband Source, 1X4 Optical Switch•Variable Optical Attenuator, Wavelength Meter•SOA Driver, SLED Driver, Pump LD Driver•Pattern Generator & BERT, SFP Transceiver Driver•4Channel Optical Return Loss Meter (Light Source & Power Meter)

  • LED Photoreactors

    Luzchem Research Inc.

    Luzchem's LED exposure tools allow photochemists and photobiologists to work with their choice of broad or narrowband visible dimmable light sources. Choose from a variety of broadband white LEDs or from our selection of narrowband blue, green, yellow and red LEDs.

  • Pump Laser Diode Driver

    S-110 - Notice

    •LD Driver, EDFA, ASE Broadband Source, 1X4 Optical Switch•Variable Optical Attenuator, Wavelength Meter•SOA Driver, SLED Driver, Pump LD Driver•Pattern Generator & BERT, SFP Transceiver Driver•4Channel Optical Return Loss Meter (Light Source & Power Meter)

  • Light Sources and Amplifiers

    EXFO Inc.

    Light sources simulate the optical voice, video and data signals of real-life service applications, which is why they are used in various types of tests. Discover a broad range of products that cater to various testing requirements: singlemode or multimode, polarized or non-polarized, broadband or narrowband, tunable, ITU-wavelength-centered and much more.

  • Tunable Deuterium and Tungsten-Halogen Light Sources

    HORIBA, Ltd.

    Deuterium and Tungsten-Halogen tunable light sources are convenient and affordable solutions for your laboratory experiments. Their optimized optical design, delivers efficient and power stabilized broadband optical power with variable aperture and selectable bandwidth with wavelength ranging from 180 nm up to 2 micron depending on your choice of the lamp.

  • Spectrometer - OSA

    HighFinesse GmbH

    HighFinesse optical spectrometers LSA and HDSA are designed to analyse the multi-line or broadband spectrum of (un-)known light sources like cw and pulsed lasers, gas discharge lamps, super luminescence diodes, semiconductor laser diodes and LEDs. They are suitable to analyze the spectrum of telecom signals, resolve Fabry-Perot modes of a gain chip, and produce a spectral measurement of gas absorption.

Get Help